The FLT93B BASIC insertion type FlexSwitch for flow and temperature monitoring represents the first true technological breakthrough in thermal technology in over a decade. FCI is the only thermal manufacturer providing temperature compensation to ensure set point accuracy for process temperatures that vary up to ±100°F. The FLT93B is easily field-configured, providing unparalleled flexibility, accuracy and stability for all multiple process sensing and switching requirements.

The FLT93B BASIC flow switch is available with all of the below listed standard features for a very attractive price and with quick delivery as soon as 2 business days ARO.

Product Details

For Flow Service - Setpoint Range:

  • Water-based Liquids:

0.01 to 3.0 fps [0.003 to 0.9 mps]

  • Hydrocarbon-based Liquids:

0.01 to 5.0 fps [0.003 to 1.5 mps]

  • Air/Gas:

0.25 to 120 sfps [0.08 to 37 smps] at standard conditions of 70° F [21.1° C] and 14.7 psia [1.013 bar(g)].

Accuracy: (whichever reading is higher)

  • Liquids: ± 0.5% reading or ± 0.04 fps [± 0.012 mps]

  • Gases: ± 0.5% reading or ± 2 sfps [± 0.06 nmps]

For Temperature Service:
Accuracy: ± 2° F [±1° C]
Repeatability: ± 1° F [± 0.6° C]

Response Time: As low as 3 seconds.

Enclosure: NEMA 4X/IP67 Rated. Standard: Polyester power coated aluminum, with 1" NPT conduit
port. Optional: Stainless steel. Optional: 2 conduit port, aluminum.

Compliances and Agency Approvals: FM, FMc, ATEX, IECEx, EAC/TR CU, Inmetro, EQM/ECAS. CE Marking. PED, CRN. (UKCA, UKEX pending)
Meets EC directives for EMC and LVD. Probe complies with Canadian Electrical code requirements of ANSI/ISA 12.27.01-2011 as a single seal device.
 

FM/FMc:
 XP, Class 1, Div. 1 Groups B,C,D, T3A or T4 Ta ≤60°C

EAC/TR CU

 
DIP, Class II/III, Div. 1, Groups E,F,G, T3A or T4 Ta ≤60°C
Nonincendive for Class I, II and III, Division 2, Groups A,B,C,D,E,F, and G, T3A or T4 -40°C ≤Ta≤60°C; hazardous (classified) locations, indoors and outdoors.
Type 4X
 
ATEX:Integral:                        II 2 G  Ex db IIC T4…T2 Gb
                                     II 2 D  Ex tb IIIC T135°C…T300°C Db
IECEx:
(EQM/ECAS)
Integral:                        Ex db IIC T4…T2 Gb
                                     Ex tb IIIC T135°C…T300°C Db                 

Optional N.I.S.T. Flow Calibration Services
Factory N.I.S.T. calibration in air or water is available as an option for customer specified setpoint(s) or a flow curve based on the media ranges specified above.
 

Flow Element

Materials of Construction: All welded 316L stainless steel for all wetted surfaces.

Process Connection: 0.75 inch male NPT

Insertion Length:

  • 1.2 inch [30 mm]

  • 2 inches [51 mm]

  • 4 inches [102 mm]


Operating Temperature: -40° to +350° F [-40° to +177° C]

Operating Pressure: To 3500 psig [240 bar(g)]
 

Control Circuit

Operating Temperature: -4° to +140° F [-20° to +60° C]

Universal AC/DC supply. Input terminals and jumpers on circut board select specific power.
 

AC108-132V13W, 100mA max.
AC207-253V*14W, 50mA max.
AC18-28V7W, 230mA max.
DC21-30V7W, 230mA max.

* AC mains preset by factory: FM & FMc as 108-132 Vac; All others as 207-240 Vac 

Relay Contacts: Field configurable dual SPDT or single DPDT rated 6 amps at 115 Vac, 240 Vac or 24 Vdc.

Output Signal: Analog DC voltage related to flow or level/interface signal and proportional to temperature.

Electrical Connection: 1 inch female NPT 

Quick Access