ST80/ST80L Mass Flow Meters
SKU: ST80/ST80L
ST80 is a high performance, rugged thermal dispersion technology air/gas flow meter that combines ultra-reliable, feature-rich electronics, and FCI innovations such as Adaptive Sensing Technology™ (AST™) with the industry's most extensive selection of application-matched flow sensors, including FCI's patented "FPC" sensor for compressed air and new "wet gas" flow element, to provide a truly superior solution for industrial processes and plant applications. The ST80 further combines these features with a robust, rugged transmitter enclosure and industry’s broadest selection of process connections to provide longest service life and ease-of-installation in your installation’s pipe or duct.
The ST80 Series transmitter’s outputs are a match to your DCS, PLC, SCADA, recorder, or alarm system. Whether your output needs are traditional 4-20 mA analog or advanced digital bus communications such as HART, Foundation Fieldbus, PROFIBUS PA, PROFIBUS DP, or Modbus, ST80 has you covered. Then for local display, the ST80’s graphical, backlit LCD is unmatched in showing what’s happening in the pipe. Flow rate, totalized flow, and temperature are continuously displayed in both a digital and bar graph presentation, while alarms and/or diagnostic messages will display as needed to alert operators.
Features
Direct mass flow measuring
Flow rate, totalized flow, temperature
No moving parts, virtually no maintenance
Patented AST™ thermal measuring mode
Process temperatures up to 850°F [454°C]
Analog outputs and bus communications
Global agency approvals for hazardous Ex installations
SIL 1 compliant
Graphical multivariable LCD readout
3-point in-situ calibration drift check
Exclusive wet gas/rain shield sensor option
Integral or remote mounting
Aluminum or stainless steel enclosures
Product Details
Measuring Capability: Flow rate, total flow and temperature
Basic Styles
ST80: Insertion, single-point (for pipe diameters > 2 inches [51 mm])
ST80L: In-line (spool piece), single-point (for pipe diameters 1 inch to 2 inches [25 mm to 51 mm])
Flow Measurement Range
Insertion Style: 0.25 SFPS to 1000 SFPS [0,07 NMPS to 305 NMPS]
ST80L In-line: 0.0062 SCFM to 838 SCFM [0,01 Nm3/h to 1425 Nm3/h]
Air at standard conditions; 70°F psia and 14.7 psia [0°C and 1,01325 bar (a)]
Temperature Measurement Range
Up to 850°F [454°C] commensurate with element; see Operating Temperature in Flow Element specification
Media: all gases that are compatible with the flow element materials
Accuracy:
Flow: ± 1.0% reading, ± 0.5% full scale
Temperature: ±2 °F [± 1.1°C] (display only, flow rate must be greater than 5 AFPS [1,5 m/sec])
Temperature Coefficient
With optional temperature compensation; valid from 10% to 100% of full scale calibration
Flow: Maximum ± 0.015% of reading / °F up to 850°F [± 0.03% of reading / °C up to 454°C]
Repeatability
Flow: ± 0.5% reading
Temperature: ±1 °F [±1°C] (flow rate must be greater than 5 AFPS [1,5 NMPS])
Response Time (Flow): 1 sec. to 63% of final value (1 step change) typical with -FP or -FPC type flow element operating in AST™ mode
Turndown Ratio
Normally factory set and field adjustable from 2:1 to 100:1 within calibrated flow range.
Temperature Compensation
Standard: ± 30°F [± 16°C]
Optional: ± 100°F [± 55°C]
Calibration: Performed on flow stands using equipment traceable to NIST and ISO/IEC 17025
Agency Approvals:
| FM/FMc: | Class I, Division 1, Explosion proof, Groups B,C,D Class II/III, Division 1, Dust ignition proof, Groups E,F,G Class I, Division 2, Nonincendive, Groups A,B,C,D Class II, Division 2, Nonincendive, Groups E,F,G Class III, Division 1,2, Dust ignition proof, indoor/outdoor Hazardous (Classified) locations Type 4x/IP67 (per NEC 500) |
| ATEX: | II 2 G Ex db IIC T6...T1 Gb Ta= -40°C TO 65°C, IP66/67 II 2 D Ex tb IIIC T85°C...T450°C Db Ta= -40°C TO 60°C, IP66/67* |
| IECEx: | Ex db IIC T6...T1 Gb Ta= -40°C TO 65°C, IP66/67 Ex tb IIIC T85°C...T450°C Db Ta= -40°C TO 60°C, IP66/67* |
| Other: | UKEX, EAC/TR CU, NEPSI, EMSA EQM-Ex, CE Mark, UKCA, CPA, CRN, Pressure Directive 032/2013 (Model ST80L) Complies with Canadian Electrical code requirements of ANSI / ISA 12.27.01-2011 as a single seal device |
* Available in standard and elevated T-ratings
| * T-Rating (Probes) | Process Temperature Range | |
| Standard | Optional Elevated** | |
| T4/T135°C | -40°C to +65°C | -40°C to +89°C |
| T3/T200°C | -40°C to +115°C | -40°C to +154°C |
| T2/T300°C | -40°C to +177°C | -40°C to +254°C |
| T1/T450°C | -40°C to +365°C | -40°C to +404°C |
** With elevated T-rating, instruments will be fixed in AST measuring mode, not field changeable into CP mode.
SIL/IEC 61508: SIL 1 compliant, SFF 71.1% to 79.1%
Other: Follows best practices and guidelines as set forth in ISO 14511; Complies with ISO 14164
Flow Element
Material of Construction
All-welded 316L stainless steel; optional Hastelloy-C276
Operating Pressure
Model ST80 (Insertion style)
Metal ferrule: 1000 psig [70 bar (g)]
Teflon ferrule: 150 psig [10 bar (g)] (200°F [93°C] maximum)
Fixed Connection NPT: 1000 psig [70 bar (g)]
Fixed Connection Flanged: per flange rating
Model ST80L (inline style): 1000 psig [70 bar (g)]
Operating Temperature (Process)
Model ST80 (Insertion style)
Flow Elements (– FPC, – FP and – S):
-40°F to 350°F [-40°C to 177°C]
-40°F to 500°F [-40°C to 260°C]
-40°F to 850°F [-40°C to 454°C]
Wet gas/rain flow element: -40°F to 350°F [-40°C to 177°C]
Model ST80L (In-line Style): -40°F to 257°F [-40°C to 125°C]
Process Connections:
Compression Fittings Model ST80
3/4" or 1" MNPT, stainless steel with adjustable Teflon ferrule or metal ferrule; or flanged tapped and threaded for 3/4" fitting, ANSI or DIN flanges.
Compression fittings not available with 850°F [454°C] temperature versions.
Retractable Packing Glands
Low pressure 50 psig [3,5 bar (g)] or medium pressure 500 psig [34 bar (g)] with graphite or Teflon packing material; 1 1/4" MNPT or ANSI or DIN flange
Teflon packing required when process media is ozone, chlorine or bromine.
Remote configuration required with medium pressure packing gland.
Fixed Fittings / All Welded
1" male NPT or ANSI or DIN flange
Insertion Length:
Field adjustable lengths: (probe is etched with depth ruler in both inches and mm)
1" to 6" [25 mm to 152 mm]
1" to 12" [25 mm to 305 mm]
1" to 21" [25 mm to 533 mm]
1" to 36" [25 mm to 914 mm]
1" to 60" [25 mm to 1524 mm]
Fixed lengths: from 2.6" to 60" [66 mm to 1524 mm]
Model ST80L In-line Flow Tube
Flow element is threaded and keyed in an in-line flow tube, calibrated and supplied as a spool-piece; options include low flow injection tubes and built-in Vortab flow conditioners for optimum low flow rangeability and performance
Size: 1" diameter tubing; 1", 1 1/2" or 2" schedule 40 pipe; 1" schedule 80 pipe
Length: 9 nominal diameters
Process Connections: Female NPT, MNPT, ANSI or DIN flanges, or butt weld prepared
Option: Flanges sized for flow tube
Remote Transmitter Configurations:
Transmitter may be mounted remotely from flow element using interconnecting cable (up to 1000' [300 m])
Flow Transmitter
Operating Temperature
-40°F to 150°F [-40°C to 65°C]
Input Power:
AC: 85 Vac to 265 Vac, 50 Hz to 60 Hz; 10 watt maximum
DC: 24 Vdc ± 20%; 9 watt maximum
Outputs (Standard, Included)
Analog: Two (2) 4-20 mA* user assignable to flow rate or temperature. Outputs are user programmable to full flow range or subsets of full flow range.
* Outputs are isolated and have fault indication per NAMUR NE43 guidelines, user selectable for high (>21.0 mA) or low (<3.6 mA)
Digital:
Standard: HART (v7 compliant), Modbus RS-485 and USB Serial I/O.
Optional: (Can be added to above) Foundation Fieldbus H1, PROFIBUS-PA, or PROFIBUS-DP
(Note: Only one bus comm, HART, Modbus, Fieldbus or PROFIBUS can be active at same time)
Enclosures:
Main Transmitter / Electronics:
NEMA 4X, IP66/67; polyester powder coated, ≤0.4% CU, low/no copper content* aluminum or optional in stainless steel; 4 conduit ports threaded as 1/2" NPT or M20x1.5; 7.74" x 5.40 " x 5.00" [196,6 mm x 137,2 mm x 127 mm]. (*standard effective April 2023)
Local Enclosure (Remote Configuration):
Model ST80 without packing gland option and Model ST80L
NEMA 4X, IP67; polyester powder coated aluminum or stainless steel; 2 conduit ports threaded as 1/2" NPT or M20x1.5; 3.75" x 4.00" x 3.24" [95 mm x 102 mm x 82 mm]
Models ST80 with packing gland option:
NEMA 4X, IP67; polyester powder coated aluminum or stainless steel; 1 conduit port threaded as 1" NPT or M20x1.5; 5.40" x 4.82" [137.2 mm x 122 mm]
Readout/Display (Optional):
Large 2" x 2" [50 mm x 50 mm] LCD; digital plus bar graph and engineering units
Digital displays of flow rate, total flow, temperature and pressure (with STP models); user selectable for engineering units
Analog bar graph of flow rate
Alarm status indication
User programmable 20 alphanumeric character field associated with each calibration group
Set-Up & Service mode displays text and service codes
Backlighted
Display is electronically rotatable in 90° increments to optimize viewing angle
Touch Button/Keypad (Optional)
Four (4) optical touch buttons
For user programming of instrument set-up and service interrogation
Activation through front window – no need to open enclosure to access or activate
Set and adjust the meter or interrogate diagnostics in-situ, even in Hazardous Ex (Div.1/Zone1) installation.
Note: If readout/display with buttons not ordered, all user set-up and service diagnostics interrogation must be done via computer link to bus comm and/or USB port.
Quick Access