ST110A Mass Flow Meter
SKU: ST110A
ST100A is high performance thermal dispersion technology gas flow meter that combines the most feature- and function- rich electronics, and innovations such as FCI patented Adaptive Sensing Technology™ (AST™), with the industry's most advanced flow sensors such as FCI patented "FPC" flow element for compressed air flow and new "wet gas" sesnor to achieve a truly state-of-the-science flow metering solution for industrial processes and plant applications.
The ST100A series transmitter is unsurpassed in meeting your current and future need for outputs, process information and communications. Whether your output needs are traditional 4-20 mA analog, frequency/pulse, or advanced digital bus communications such as HART, Foundation fieldbus, PROFIBUS, or Modbus, ST100A has you covered. ST100A's bus communications have been certified by and are registered devices with HART and Foundation Fieldbus. In addition, Emerson Process (Delta V), Yokogawa and ABB (800xA) (see page 6) have tested and verified ST100A Series' Foundation Fieldbus interoperability with their systems.
Then there's ST100A's display/readout, which brings new meaning to the term process information. Simply, the ST100A's graphical display provides the most comprehensive information on the process measurements and conditions of any thermal flow meter available - see the ST100A close-up page for all the details.
To complete the solution, ST100A flow elements and process connections ensure the best possible measurements and effective installation. FCI flow element designs have been perfected and optimized through six decades of R&D and real world experience in thermal dispersion technology and flow metering applications. With thermal dispersion there are no moving parts to foul or clog. This results in the greatest reliability and valuable savings on maintenance.
Fast response, accuracy, repeatability and long-life are hallmarks of FCI flow elements available with ST100A. And, all new are the STP models, which add pressure measurement. Mass flow, temperature and pressure in a single tap-point thermal dispersion meter… An industry first and FCI exclusive! Then, consider other ST100A Series exclusives like dual-element measuring systems and FCI’s patented VeriCal option that provides significant cost and time savings by performing dynamic calibration verification in-situ, without ever removing the instrument from the process. To ensure both ease of installation and a match with your process conditions, ST100A offers a comprehensive selection of process connections and installation options.
Product Details
Measuring Capability
ST1XXA Models: Flow rate, total flow and temperature
STP1XXA Models: Flow rate, total flow, temperature and pressure
Basic Styles
ST100A: Insertion, single-point
ST100AL: In-line (spool piece), single-point
ST102AA: Insertion, dual-element averaging system
ST110A: Insertion, single-point with VeriCal™ capability
ST112AA: Insertion, dual-element averaging system with VeriCal™ capability
STP100A: Insertion, single-point with pressure measurement
STP110A: Insertion, single-point with pressure measurement and VeriCal™ capability
Flow Measurement Range
Insertion Style: 0.25 SFPS to 1000 SFPS [0,07 NMPS to 305 NMPS]
ST100AL In-line: 0.0062 SCFM to 838 SCFM [0.01 Nm3/h to 1425 Nm3/h]
Air at standard conditions; 70°F psia and 14.7 psia [0°C and 1,01325 bar (a)]
Temperature Measurement Range
Up to 850°F [454°C] commensurate with element; see Operating Temperature in Flow Element specification
Pressure Measurement Range (STP Models)
Available Ranges:
0 psig to 50 psig [0 bar (g) to 3,4 bar (g)]
0 psig to 160 psig [0 bar (g) to 11 bar (g)]
0 psig to 500 psig [0 bar (g) to 34 bar (g)
0 psig to 1000 psig 0 bar (g) to 70 bar (g)]
Media: all gases that are compatible with the flow element materials
Accuracy:
Flow: ± 0.75% reading, ± 0.5% full scale
Temperature: ± 2 °F [± 1,1 °C] (display only, flow rate must be greater than 5 AFPS [1,5 m/sec])
Pressure (STP Models): ± 1.0% of span
Temperature Coefficient
With optional temperature compensation; valid from 10% to 100% of full scale calibration
Flow: Maximum ± 0.015% of reading / °F up to 850°F [± 0.03% of reading / °C up to 454°C]
Repeatability
Flow: ± 0.5% reading
Temperature: ± 1 °F [± 1°C] (flow rate must be greater than 5 AFPS [1,5 NMPS])
Pressure (STP Models): ≤ 0.1% of span
Response Time (Flow): 1 sec. to 63% of final value (1 step change) typical with -FP or -FPC type flow element and AST electronics.
Turndown Ratio
Normally factory set and field adjustable from 2:1 to 100:1 within calibrated flow range; up to 1000:1 possible with factory evaluation of application
Temperature Compensation
Standard: ± 30°F [± 16°C]
Optional: ± 100°F [± 55°C]
Calibration: Performed on flow stands using equipment traceable to NIST and ISO/IEC 17025
Agency Approvals:
FM/FMc: Class I, Division 1, Explosion proof, Groups B,C,D
Class II/III, Division 1, Dust ignition proof, Groups E,F,G
Class I, Division 2, Nonincendive, Groups A,B,C,D
Class II, Division 2, Nonincendive, Groups E,F,G
Class III, Division 1,2, Dust ignition proof, indoor/outdoor Hazardous (Classified) locations
Type 4x/IP67 (per NEC 500)
ATEX: EX d IIC Gb T6/T1 Ta= -40°C TO 65°C
Ex tb IIIC T85°C/T450°C Db Ta= -40°C TO 65°C, IP67
IECEx:
(ECSA EQM Ex.) II 2 G Ex d IIC Gb T6/T1 Ta= -40°C TO 65°C, IP67
Other: NEPSI, EAC/TR CU, Kazakh MPA (Kazakhstan), CRN, Inmetro, CPA, EQM/ECAS, UKCA(UKEX) CE Marking
Complies with Canadian Electrical code requirements of ANSI / ISA 12.27.01-2011 as a single seal device.
Ex-rated pressure transducer STP models:
FM/CSA: Class 1, Division 1, Groups A,B,C,D
Dust ignition proof for Class 1, Division 1, Groups E,F,G
ATEX: 2 G Ex d C T4, Ex d IIC T5, Ex d IIC T6
Flow Element
Material of Construction
All-welded 316L stainless steel; optional Hastelloy-C276
Operating Pressure
Insertion Types
ST Models
Metal ferrule: 1000 psig [70 bar (g)]
Teflon ferrule: 150 psig [10 bar (g)] (200°F [93°C] maximum)
Fixed Connection NPT: 1000 psig [70 bar (g)]
Fixed Connection Flanged: per flange rating
STP Models: per above or pressure sensor rating, whichever is less
Inline Type (Model ST100AL): 1000 psig [70 bar (g)]
Operating Temperature (Process)
ST100A, ST102AA Insertion Style
All Flow Elements (– FPC, – FP and – S):
-40°F to 350°F [-40°C to 177°C]
-40°F to 500°F [-40°C to 260°C]
-40°F to 850°F [-40°C to 454°C]
ST110A, ST112AA Insertion Style
– FP Style Flow Element:
-40°F to 350°F [-40°C to 177°C]
-40°F to 500°F [-40°C to 260°C]
STP Series Insertion Style
– FP Style Flow Element:
Standard Pressure Sensor: -32°F to 176°F [0°C to 80°C]
Ex-rated Pressure Sensor: -22°F to 212°F [-30°C to 100°C]
ST100AL In-line Style
– FP and – S Style Flow Element:
-40°F to 250°F [-40°C to 121°C]
Process Connection:
Compression Fittings Models ST100A and ST102AA only
3/4" or 1" MNPT, stainless steel with adjustable Teflon ferrule or metal ferrule; or flanged tapped and threaded for 3/4" fitting, ANSI or DIN flanges.
Compression fittings not available with 850°F [454°C] temperature versions of ST100A or ST102AA
Low pressure 50 psig [3,5 bar (g)] or medium pressure 500 psig [34 bar (g)] with graphite or Teflon packing material; 1 1/4" MNPT or ANSI or DIN flange
Teflon packing required when process media is ozone, chlorine or bromine.
Remote configuration required with medium pressure packing gland.
Fixed Fittings / All Welded
1" male NPT or ANSI or DIN flange
Insertion Length:
Field adjustable lengths:
1" to 6" [25 mm to 152 mm]
1" to 12" [25 mm to 305 mm]
1" to 21" [25 mm to 533 mm]
1" to 36"